Anvil STEEL PIPE CLAMPS Fig. 212 Medium Pipe Clamp

  • Size Range: 1⁄2" through 30"
  • Material: Carbon steelFinish: Plain or Hot-Dip Galvanized with Zinc Plated Bolts & Nuts
  • Service: Recommended for suspension of cold pipe lines or hot lines whereno insulation is required
  • .Maximum Temperature: Plain 750° F, Galvanized 450° F
  • Approvals: Complies with Federal Specification A-A-1192A (Type 4)WW-H-171-E (Type 4), ANSI/MSS SP-69 and MSS SP-58 (Type 4).UL, ULC Listed and FM Approved (Sizes 3⁄4" - 8").
  • Installation: Normally used with weldless eye nut Fig. 290, page 102 or eye rod.
  • Features:• Clamps tightly to pipe.• Wide range of sizes.• Equal gap design on many sizes.
Screenshot (34)

Anvil STEEL PIPE CLAMPS Fig. 212FP Earthquake Bracing Clamp

  • Size Range: 2 1⁄2" through 12"
  • Material: Carbon steel
  • Finish: Plain or Hot-Dip Galvanized with Zinc Plated Bolts & Nuts
  • Service: For seismic bracing, to be used with Fig. 113 brace fitting.Pipe clamp bolt holes are designed to match holes in brace fitting.
  • Maximum Temperature: Plain 750° F, Galvanized 450° F
  • Approvals: Complies with Federal Specification A-A-1192A (Type 4)WW-H-171-E (Type 4), ANSI/MSS SP-69 and MSS SP-58 (Type 4).
  • Installation: Designed for use with Fig. 113 brace fitting, see page 76.
  • Ordering: Specify pipe size, figure number, name and finish.
  • Note: The “C” gap dimension should be used at the upper and lowerlocations to ensure proper installation of the clamp.
Screenshot (35)

Anvil STEEL PIPE CLAMPS Fig. 216 Heavy Pipe Clamp

  • Size Range: 3" through 42"
  • Material: Carbon steel
  • Finish: Plain or Hot-Dip Galvanized with Zinc Plated Bolts & Nuts
  • Service: Recommended for suspension of pipe lines where no insulation is required.
  • Maximum Temperature: Plain 750° F, Galvanized 450° F
  • Approvals: Complies with Federal Specification A-A-1192A (Type 4)WW-H-171-E (Type 4), ANSI/MSS SP-69 and MSS SP-58 (Type 4).
  • Installation: Normally used with welded eye rod or with weldless eye nutFig. 290, see page 102.
  • Features:• Designed for heavy load up to 750° FOrdering: Specify pipe size, figure number, name and finish
  • Note: If different loads or dimensions are required, refer to Fig. 42 SD non-standardtwo bolt pipe clamp.
Screenshot (36)

Anvil STEEL PIPE CLAMPS Fig. 295 Double Bolt Pipe Clamp

  • Size Range: 3⁄4" through 36"
  • Material: Carbon steel
  • Finish: Plain or Hot-Dip Galvanized with Zinc Plated Bolts & Nuts
  • Service: Recommended for suspension of pipe requiringinsulation within the limitation of temperature and loadsshown below.
  • Maximum Temperature: Plain 750° F, Galvanized 450° F
  • Approvals: Complies with Federal Specification A-A-1192A(Type 3), WW-H-171-E (Type 3), ANSI/MSS SP-69 andMSS SP-58 (Type 3).
  • Installation: Attachment to the clamp may be madewith a welded eye rod Fig. 278, page 98 or the weldlesseye nut Fig. 290, see page 102
  • .Features:• Sizes 6" and above accommodate up to 4" thickinsulation.• Figure 41SD will accommodate larger insulationthicknesses, loads and dimensions.
Screenshot (37)

Anvil SOCKET CLAMPS Fig. 595 Socket Clamp for Ductile Iron or Cast Iron Pipe

  • Size Range: 4" through 24"
  • Material: Two carbon steel half bands and four bolts and nuts.
  • Finish: Plain or Hot-Dip Galvanized with Zinc Plated Bolts & Nuts
  • Service: Clamps ductile or cast iron mechanical joint piping ormechanical joint or socket joint fittings together to preventseparation or distortion of pipe line under excessive water pressure.
  • Approvals: Complies with Federal Specification A-A-1192A (Type 8),ANSI/MSS SP-69 and MSS SP-58 (Type 8). Complies with therequirements of the National Fire Protection Association StandardNFPA-24 for Outside Protection.
  • Ordering: Specify pipe size, figure number, name and finish
Screenshot (38)

Anvil SOCKET CLAMPS Fig. 600 Socket Clamp for Ductile Iron or Cast Iron Pipe

  • Size Range: 3" through 24" pipe
  • Material: Two carbon steel halfbands and two bolts and nuts.
  • Finish: Plain or Hot-Dip Galvanized with Zinc Plated Bolts & Nuts
  • Service: Clamps joints of socket fittings together to preventdistortion of pipe line under excessive water pressure.
  • Approvals: Complies with Federal Specification A-A-1192A (Type 8),ANSI/MSS SP-69 and MSS SP-58 (Type 8).
  • Features: An economical method of anchoring joints of socketfittings when used on other than fire protection work
  • .Ordering: Specify pipe size, figure number, name and finish.
Screenshot (39)

Anvil BEAM CLAMPS Fig. 95 C-Clamp with Locknut

  • Size Range: 3⁄8" and 1⁄2"
  • Material: Carbon Steel
  • Finish: Plain or Zinc Plated
  • Service: Designed for fastening flange of “W” and “M” beam. Bottom hole tappedto accommodate hanger rod.
  • Approvals: Complies with Federal Specification A-A-1192A (Type 23)WW-H-171-E (Type 23), ANSI/MSS SP-69 and MSS SP-58 (Type 23).UL Listed (Sizes 3⁄8").FM Approved (Sizes 3⁄8" - 1⁄2").
  • Installation: Follow recommended set screw torque values per MSS-SP-69(See table on page 248)
  • Ordering: Specify rod size, figure number, name and finish.
Screenshot (41)

Anvil BEAM CLAMPS Fig. 94 Wide Throat Top Beam C-Clamp

  • Size Range: 5⁄8" and 3⁄4"
  • Material: Ductile iron body, hardened steel cup point set screw and locknut.
  • Finish: Plain or Zinc Plated (Hot-Dip Galvanized optional)
  • Service: Recommended for use under roof installations with bar joist typeconstruction, or for attachment to the top flange of structural shapeswhere the vertical hanger rod is required to be offset from the edge ofthe flange and where the thickness of joists or flange does not exceed 1 5⁄16".
  • Approvals: Complies with Federal Specification A-A-1192A (Type 19)WW-H-171-E (Type 19), ANSI/MSS SP-69 and MSS SP-58 (Type 19), UL Listed.
  • How to size: Size of clamp is determined by size of rod to be used.
  • Installation: Follow maximum recommended set screw torque valuesper MSS-SP-69. (See tables on page 248)
  • Features:• Provides clamping to bar joists which are directly under roof installations.• Provides for vertical hanger rod installed offset from the edge of the beam flange.• Malleable iron body assures full thread engagement of rod.
Screenshot (42)

Anvil BEAM CLAMPS Fig. 227 Top Beam Clamp

  • Material: Carbon steel jaw, hook rod with nut, lock washerand plain washer.
  • Finish: Plain
  • Service: Recommended for use on top flange of beam and rooftrusses where the flange thickness does not exceed 0.81".Approvals: Complies with Federal Specification A-A-1192A (Type 25),ANSI/MSS SP-69 and MSS SP-58 (Type 25). UL Listed (rod sizes 3⁄8" & 1⁄2")and FM 
  • Approved when used with 3⁄8" rod size.
  • Features:• Two jaw sizes fit beam flanges thickness from 0.25" to 0.81".• Clamp firmly holds to beam providing safe and extremelyeconomical means of supporting small piping from thetop flange of steel beams and roof trusses.
Screenshot (43)

Anvil BEAM CLAMPS Fig. 14 Adjustable Side Beam Clamp

  • Size Range: 3⁄8" through 5⁄8"
  • Material: Carbon steel
  • Finish: Plain or Zinc Plated
  • Service: Recommended for supporting pipe from the bottom flange of beams.
  • Approvals: Complies with Federal Specification A-A-1192A (Type 27)WW-H-171-E (Type 54), ANSI/MSS SP-69 and MSS SP-58 (Type 27).
  • Ordering: Specify rod size, figure number, name and finish
Screenshot (44)

Anvil BEAM CLAMPS Fig. 217 Adjustable Side Beam Clamp

  • Size Range: 3" through 7 5⁄8"
  • Material: Carbon steel
  • Finish: Plain
  • Service: To be used where it is necessary for the hanger rodto run vertically close to the beams edge, eliminating drillingof holes in structural members
  • Components: Top slide, bottom hook, nut and bolt – assembled.
  • Design: Can be adjusted to fit various beam flange widthsand thicknesses.
  • Approvals: Complies with Federal Specification A-A-1192A(Type 25), ANSI/MSS SP-69 and MSS SP-58 (Type 25).
  • Ordering: Specify size, figure number, type, name.
Screenshot (45)

Anvil BEAM CLAMPS Fig. 227 Top Beam Clamp Fig. 218 Malleable Beam Clamp without Extension Piece

  • Material: Malleable iron jaw, steel tie rod, nuts and washer.
  • Finish: Plain or Zinc Plated (Hot-Dip Galvanized optional)
  • Service: Recommended for attachment to structural steel.Use in conjunction with beams where beam widths are from2 3⁄8" minimum to 7" maximum and flange thickness doesnot exceed 0.60".
  • Approvals: Complies with Federal Specification A-A-1192A (Type 30)WW-H-171-E (Type 30), ANSI/MSS SP-69 and MSS SP-58 (Type 30).UL, ULC Listed (Sizes 3⁄4" - 12" pipe size, when used with the Fig. 157extension piece 3⁄8" - 7⁄8" rod sizes).FM Approved (Sizes 3⁄4" - 4” pipe size, when used with the Fig. 157extension piece 3⁄8" rod size).
  • Features:• Functional design insures proper fit for all beam sizes.• Tie rod locks clamp in place when nuts are tightened.• Ordering and stocking simplified because of one universal size.• Design allows hanger rod to swing from vertical providingflexibility at the beam clamp.
Screenshot (46)