Hazardous Duty™ Division 1 Explosion Proof

  • 10:1 Variable torque, 2:1 Constant torque
  • 1.15 Service Factor• Class F insulation
  • Meets temperature code T2A
  • All Cast iron construction
  • Shaft slinger
  • External surface treated with epoxy paint
  • Name plated 60/50 Hz, 190/380 Volts, at next lower HP
  • See modification section for addition of C-Face kits (254T-445T)
  • Ball bearings (except as noted)
  • UL Listed File No. E12044
  • CSA Certified File No. LR47504
  • Two year warranty
Screenshot (23)

Inverter (Vector) Duty: microMAXTM

  • Designed to replace PMDC motors (when used with a VFD)
  • Constant horsepower to twice base speed (RPM)
  • Class H insulation with CR200 magnet wire
  • Removable base for C-Face footless mounting, as noted
  • Continuous duty at 40ºC ambient
  • Quick Connect terminal board, as noted
  • Top mounted conduit box found on PMDC motors
  • Eliminates brush and commutator maintenance
  • UL Recognized, CSA Certified, and CE Mark
  • Three year warranty
Screenshot (24)

Inverter (Vector) Duty: Black Max® Hazardous Duty™

  • MAX GUARD® Class F insulation system
  • Constant torque operation from 0 to base speed on vector drive
  • Constant HP operation to twice base RPM
  • Continuous duty at 40ºC ambient
  • Optimized for operation with IGBT inverter (NEMA Design A)
  • Normally closed thermostats (one per phase, Class F)
  • Ball Bearings
  • Top mount (F3) conduit box included, shipped loose
  • No Encoder Provisions provided
  • Meets temperature code T3B
  • UL listed, under file #E12044
  • CSA certified, under file numbers LR47504 and LR21839
  • Three year warranty
Screenshot (25)

Inverter (Vector) Duty

  • BEI H38 explosion proof encoder 1024 ppr, Class I Groups C & D,Class   II Groups E, F, G included
  • MAX GUARD® Class F insulation system
  • Constant torque operation from 0 to base speed on vector drive
  • Constant HP operation up to twice base speed
  • Continuous duty at 40ºC ambient
  • Optimized for operation with IGBT inverter (NEMA Design A)
  • Normally closed thermostats (one per phase, Class F)
  • Ball Bearings
  • Cast iron frame and brackets
  • F1 standard, NOT field reversible to F2
  • UL Listed File No. E12044, MC228275
  • CSA Certified File No. LR47504, MC236833
  • Meets temperature code T3B
  • Three year warranty
Screenshot (26)

Washdown, DC Permanent Magnet SCR Rated, Totally Enclosed C-Face Footed (Removable Base)

  • Class F insulation
  • NEMA C-Face with removable rigid base
  • Oversized brushes for extra long life
  • Doubled sealed, oversized ball bearings
  • Corrosion resistant 303 stainless steel shaft
  • “V” ring Forsheda seals• High temperature, moisture resistant lubricant
  • Exterior and interior components protected with enamel & polyester  
  • Stainless steel nameplate
  • USDA approved white epoxy paint
  • UL Recognized and CSA Certified
Screenshot (27)

Brake Motors, Single Phase Totally Enclosed, C-Face Footed (Removable Base)

  • Fail-safe, spring set Stearns 56 Series brake for holding or stopping
  • Brake has manual wear adjustment for longer pad life
  • Manual release lever on rear of brake housing
  • Brake leads are terminated at the brake
  • Universal mounting, no modifications needed
  • Brake coil voltage matches motor voltages, see mod section for other brake coils
  • Ball bearings, mechanically locked on shaft end
  • 1.15 Service Factor (1.0 Service Factor as noted)
  • Nameplated 60/50 hertz at next lowest horsepower
  • UL Recognized and CSA Certified
Screenshot (28)

Farm Duty / Agriculture, High Torque Single Phase, TEFC

  • Ball bearings, shaft end mechanically locked on C-face models (excludes 5K models)
  • 1.15 Service Factor (except as noted)
  • Capacitor start design for high starting torque
  • Capacitor start/capacitor run design for higher efficiency, as noted
  • Low temperature manual reset thermal protector
  • Totally enclosed and fully gasketed construction for dirty environments
  • Condensate drains
  • Shaft slinger
  • UL Recognized and CSA Certified
Screenshot (29)

Farm Duty / Agricultural Single Phase, TEAO, Direct Drive-Thru Bolt

  • Economical split phase design
  • X909 has1/2” diameter x 1.5” long shaft with flat
  • X910 and X911 have 1/2” dia. X 2-1/2” long shaft with two flats, 90 degrees apart
  • Thermal protection, as noted
  • Ball bearings
  • Fully gasketed
Screenshot (30)

PowerWash™ XT Washdown Duty, Three Phase White Epoxy, Totally Enclosed

  • 10:1 Variable torque, Constant torque speed range as listed below
  • MAX GUARD® Class F insulation system
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • Double sealed ball bearings
  • 303 Stainless steel shaft with spring loaded contact seals in each end shield(Drive end only on TENV motors)
  • Stainless steel conduit box cover, nameplate, fan guard (TEFC only)and hardware
  • Cast oversized conduit box with high temperature nitrile gaskets andthreaded entrance
  • Plugged drain holes in each endshield for all angle mounting
  • Internal corrosion resistant coatings on frame, base, endshields, rotor and stator
  • USDA-approved, white epoxy RUST-OLEUM® paint
  • UL Recognized, CSA Certified and CE Mark
Screenshot (31)

Close-Coupled Pump, JM, Three Phase Dripproof, C-

  • NEMA JM pump shaft dimensions
  • JMV frame includes drip cover for vertical mount without base
  • JM frame has rigid base, drip cover not included
  • Ball bearings, mechanically locked on shaft end
  • Continuous duty
  • 1.15 Service Factor
  • UL Recognized and CSA Certified
  • UL Listed for Fire Pump applications (except as noted)
Screenshot (32)

Fire Pump, Three Phase Dripproof, Rigid Base

  • UL File EX5190, CSA File LR2025 and CE Mark
  • Ball bearings
  • 1.15 Service Factor
  • Red paint on 25 HP through 200 HP
  • NEMA Design B, Code G or less
  • Dual voltage motors have 12 leads, suitable for wye-delta or across the linestart on either voltage, or part winding start on low voltage
  • Single voltage motors have 12 leads and are suitable for wye-delta, acrossthe line, or part winding start
  • Will accept C- Face kits, see Accessories section
  • 230/460 and 460 Volt models rated for 50 HZ at next lower HP, 1.15 SF as noted
Screenshot (33)

Fan and Blower - Direct Drive, PSC, Open Air Over Belly Band Thru-Bolt, Double Shaft

  • Open frame and brackets
  • Multi-speed capability
  • Automatic reset thermal protector
  • 30” leads• CCW rotation, fixed lead end
  • 1” extended Thru-bolts both ends
  • 20” overall length
  • Length adapter kits included where noted
  • Ball bearings
  • UL Recognized and CSA Certified
  • Capacitor not included, see Accessories section
Screenshot (34)